Cerberus 8.0
Release History |Cerberus 8.5
Release History | Orion
Release History
Cerberus
8.5 (All Types) Enhancements
- Release Note History
8.5.18
- HYDRA- Hydra has been improved, including the execute function.
8.5.17
- WELL EDITOR – All types of wells may be printed.
- STRING DESIGN - All wells will appear in the list.
- ORPHEUS - The Wireline report has been improved.
- JOB MANAGER - Improvements made for handling large job logs.
- HYDRA - The Jointed Pipe fit algorithm has been improved.
8.5.16
- Changes were made to the installation capability of the program.
8.5.15
- ORPHEUS - The “Drum Crush” warning has been removed from slick line projects. A calculation lock-up issue has been resolved.
8.5.14
- ORPHEUS - Warnings have been added and improved in the Wireline report.
- STRING EDITOR – The correct outer diameter of a tapered string can now be updated.
- CERBERUS – Cerberus can now use Polish regional settings
8.5.13
- FLUID MANAGER - Cerberus version 8.0 fluids may be imported.
- HYDRA - The Orpheus calculation engine was improved to allow concurrent calculations while viewing the data table.
- WELL EDITOR – Well Editor now allows creation of a new well if the well-name has been used previously. A well can be saved even if the reservoir is removed.
- STRING MANAGER- Capacity calculations have been updated in the fatigue printout.
8.5.11
- ORPHEUS - Fluid densities can be entered in Metric Units.
- ORPHEUS - Bottom hole assembly can now be displayed in correct position in well bore.
- JP EDITOR - The JP editor can print to a PDF printer.
- JP EDITOR - The JP diagram can now be viewed in the expanded format.
Cerberus
8.0 (All Types) Enhancements
- Release Note History
8.0.30
- Orpheus - Poisson’s effect is now included in the stretch graph for RIH and POOH.
- String Manager - Strings can be organized into folders.
- Cerberus – Back-up databases can now be used.
8.0.29
- Orpheus - Added the ability to Orpheus to use Herschel Bukley fluid rheologies.
- Orpheus - Input checking was improved for the catastrophic buckling indicator.
- Hydra - The Darcy reservoir calculations have been updated to use the volume weighted average for viscosity and volume formation factors.
8.0.28
- Updated import/export functionality.
8.0.27
- Orpheus – Large set-down weights can be added to PACA.
- Orpheus – Allows calculation to proceed when annulus is filled with air and CT is filled with water.
- Cerberus – Change between military dating system and American civilian dating system allowed.
- Hydra – Changes made to allow exporting Hydra project, and for calculations to proceed without cessation with all of output printing. Flow calculation allows index selection to be “in bounds”.
- Job Manager - May use comma as a decimal separator.
8.0.26
- Well Editor- Will handle exception errors when a cell is left blank in the survey grid.
- Orpheus- Jointed Pipe editing capabilities added.
- Orpheus – Black and white printer capabilities added for lockup limits.
- Reeltrack – Change added to allow fatigue updating when the pressure is negative.
8.0.25
- Orpheus -
String editor allows .Net Framework 2.0 to be installed. The averaging function can be used while importing Orion data.
- Cerberus – Allows
the use of a comma for a decimal separator.
- String
Manager – Allows printout
of all strings with printers.
- Hercules – Projects
can be printed prior to saving.
- Hydra – Eliminated “curve does not exist error” from
well view.
- Reeltrak – Job
can be saved prior to fatigue addition.
- Job
Manager – Allows charts
to be viewed on jobs with no positive pressure.
- Well
Editor – Now allows use
of a comma for a decimal separator with metric units
and Microsoft .Net Framework
2.0 installed.
- String
Design Wizard – Allows
a complete list of wells to be displayed.
8.0.23
- Hydra – Program
will stay active when well is deleted.
- Tool Manager – Allows
creation of a new toolbox.
- Orpheus Wireline
only – Drum
crush warning is now viewable by default in the Wireline
Report.
- Orpheus CT
only – Sensivity
analysis agrees with main calculations when changing
CT diameters.
- Orpheus – Sensivity
analysis will retrieve correct list of wells and CT
strings.
- CT
only – 3.25
inch tubing from Quality Tubing has been added to the
database.
- Base Manager – All
pages will print on the Central report or the String
report.
- Well Editor – False
data gap has been corrected to allow data to be saved.
- String Manager – New
string creation is now allowed when using international
comma as a
decimal separator.
- Job Manager – Job
log chart can be displayed when the date column contains
no data.
8.0.22
- Added a new feature to enable string and job database
link to be restored if accidentally corrupted or deleted.
- Orpheus WL only – Corrected
the reel capacity calculation in the Cable Tension
Wizard when metric
units are utilized.
- PACA JP
only – Added
ability to model a temporary packer for jointed pipe
operations.
8.0.21
- Tool Manager – Eliminated
an issue that could prevent users from creating new
tools
for their toolbox.
- Orpheus – Corrected frictional
pressure drop calculation for downhole tools. This issue
was restricted to calculations
performed using versions 8.0.19 and 8.0.20 of the software.
- Well Editor – Corrected
productivity index calculation when metric units are
utilized.
- Orpheus – Eliminated
an issue that prevented some users from saving their project
organization settings to
a folder.
8.0.20
- Hydra – Eliminated
calculation error where pressure drop across the
tool was ignored if metric
units
were used.
- Hercules – Eliminated
program stability issues that could result when a project
was
deleted.
- Orpheus – Wireline
only, corrected the display of cable wrap positions
in the
Cable Tension Wizard
graph.
- String Manager – Eliminated
issue that could prevent splicing of CT strings if
metric units were used.
8.0.19
- Eliminated Microsoft.Net
Framework 2.0 incompatibility error “unable to
cast object of type ‘_CFluid[]“
- Well Editor – Eliminated
the appearance of duplicate entry’s following
saving a well to file.
- Hydra – Eliminated
error message that could appear when exporting a project.
8.0.18
- Orpheus – Corrected
CT lockup limit curve when used with tool model 2.
- Hydra – Corrected
reservoir flow calculations provided by Hydra snapshot
mode.
- PACA – Eliminated “Subscript
out of range” error that could occur when using
the permanent packer option after modeling with a temporary
packer.
8.0.17
- Hercules – Improved
stability of calculations when Ovality equals zero.
- Reeltrak – Prevent
fatigue calculation for high pressure (>25,000 PSI)
modeling situations due to lack of test data.
8.0.16
- Orpheus – Corrected
incorrect scaling of wall contact force graph in the
Wireline report.
- Orpheus – Eliminated
issue of a project possibly not appearing after file
import.
- Orpheus – Eliminated
an Orion data import issue whereby an incorrect
depth would be displayed if the imported data was scaled
in metric units.
- Hydra – Corrected
fill removal weight calculation of wellbore fill particles
suspended in fluid.
8.0.15
- Orpheus – Eliminated “Error
15” message that would intermittently occur when
modeling deeper wells containing compressible fluids/gas
inside the CT.
- String Manager – Enhanced
optical display for the fatigue viewer.
8.0.14
- Orpheus – Eliminated “Index
was outside of bounds of the array” error that
could occur when modeling a with a compressible fluid.
- Orpheus – Eliminated “index
was outside of bounds of the array” error when
utilizing the String Design wizard.
- Orpheus – Implemented
a change to improve calculations when “advanced
friction” option is utilized.
8.0.13
- String Manager – Enhance
printout so that all results of the fatigue data is
printed.
8.0.12
- Orpheus – Corrected
issue with maximum depth calculation returning a value
of zero when wellhead pressure (WHP) is increased.
- Hydra – Updated
snapshot output to avoid display of a potential incorrect
liquid pump rate following use of the Analysis wizard.
- Hydra – Modified
roughness data printout to display additional significant
digits.
- Hydra – Eliminated
an error message that would sometimes appear if
a project file was saved without a string or well being
present.
- Hydra – Improved
calculations to enable convergence on a mathematical
solution when modeling situations that include tubing
nipples.
8.0.11
- Orpheus – Disabled
ability to model with centralizers, until such time
as an improved modeling solution can be developed and
incorporated in a future update release.
- Orpheus – Eliminated
erroneous error message “Measured depth is greater
than well depth.”
8.0.10
- Orpheus – Corrected
survey data printout when metric units are being used.
- Job Manager – Eliminated
an error that could occur if job files with an apostrophe
in their name are deleted.
8.0.09
- Orpheus – Improved
stability of catastrophic buckling calculation.
8.0.08
- Orpheus – Eliminated
an issue where Wireline report incorrectly reported
a problem (red) status flag when a weakpoint is not used.
8.0.07
- Orpheus – Eliminated
the ability to access coiled tubing “Limits” functionality
when modeling in Wireline mode.
8.0.06
- Orpheus – Improved
stability of Wireline report when maximized on screen.
- Well Editor – Eliminated
error that could occur when printing survey data.
- Jointed Pipe – Enhanced
so that pipe weight will update as pipe O.D. is changed.
8.0.05
- Orpheus – Corrected
Sensitivity Analysis so that it does not provide
identical pickup weights for all modeling scenarios.
8.0.04
- Orpheus – Enhanced
String Design wizard so it can use a fluid other than water
for
the well fluid.
- Tool Manager – Eliminated
erroneous error message that could occur when creating
a new toolbox.
8.0.03
- Orpheus – Updated
Wireline report so that it does not always display
a problem (red) status flag.
8.0.02
- Orpheus – Corrected
downhole roller friction calculation.
- Job Manager - Eliminated
stability issue that could occur when closing preferences
screen.
Go
back to the update download page.
Orion 8.0 Enhancements
- Release Note History
Helpful
Hint:
Users can confirm they are operating Orion IV hardware
on their unit
by opening the Orion enclosure and noting the presence of
a Opto 22 module with a silver faceplate that contains
the label “ultimate
i/o”.
8.0.26
- Comments now displayed on a filtered data Chart.
- Corrected Speed channel gain calculation error that some users may experience (if depth channel was associated with speed) when utilizing the Calibration Wizard with Orion IV hardware.
- String name punctuation for fatigue monitoring in Cerberus now supported.
- Configuration Utility updated to provide correct outputs when configuration was saved via the Configuration Utility on Orion IV hardware.
8.0.25
- Preview now available during an Orion playback.
- Limits Monitor screen can now be resized.
- Axis labels are now available in the Limits Monitor.
- Acquiring ASCII data with extra delimiters in a data stream now available.
8.0.24
- Emergency Stop System now supported with Orion IV hardware.
- Job Monitor alarm limits now update.
- Users are now alerted when Cerberus or a selected Cerberus database is not on the PC.
- Depth channel gain calculation function in Calibration Wizard was corrected to avoid incorrect gain calculation (4x high) that some users could experience with Orion IV hardware.
- Scrolling functionality while setting hardware outputs is now fully supported.
8.0.23
- Logtool header and text displays are enhanced.
- County and State fields can now be updated in Logtool.
- Dual Gauge indicator now retains channel configurations between uses.
- Logtool balloons are enhanced during playback mode.
- Logtool balloons with point values are now available during realtime.
8.0.22
- A standard cubic feet per minute (SCF/min.) unit type is now available.
- The Rover will now show CT 12 data with the Ultimate IO.
- The ability to load memory maps dynamically is now available.
- A Print Option has been added to the file menu of the log tool.
8.0.21
- The ability for Orion to handle 12 slots with the Ultimate IO has been added.
- The Limits Monitor labels are now totally viewable.
- All derived channels will now be sent to the client in Internet Mode.
- WITS ID values are now allowed to be cleared.
- The 3rd party serial option is now available with the proper authorization code.
- Configuration utility confirmation is now available.
8.0.20
- Made ASCII over TCPIP modifications
to allow a wireless network
- Enabled a WITS input mode
8.0.19
- Enabled new Orion data base with long file name
- Completed
multiple changes to improve reliability of wireless
communication
8.0.18
- Enhanced software to eliminate potential issues if
Derived Channels were utilized as the first Data Source
in the
configuration.
- Eliminated program stability issue that
could occur if a blank IP address was used in the
Internet Data Source
configuration.
- OrionNet-enhanced software to accelerate
program response time when users zero a channel.
- Eliminated
erroneous “Demo” warning message
from appearing on the Forces monitor screen.
8.0.16
- Upgraded software to enable ReelTrak to be launched from
Orion when the Username in Windows was not defined.
- Eliminated
issue that could prevent launching of Job Monitor from
Orion.
- Eliminated issue that could prevent channels from
appearing during the import of a configuration.
- OrionNet-eliminated
an issue that could prevent proper updating of PC display
when user zeroed an analog input
channel.
- OrionNet-eliminated possibility of headings not
being associated with correct datalog columns. This issue
was
only observed to occur under a very specific set
of conditions, such as terminating the Orion program, then
subsequently
restarting Orion and appending to the same database,
and then only when multiple Orion units came online in
a order
that was different than the original Orion unit shutdown
order.
- OrionNet-enhanced the Error Detection capabilities
of the software.
- OrionNet-upgraded protocol to utilize
TCP (instead of UDP).
8.0.15
- Critical
Update for Orion IV/OrionNet Users Only -
eliminated “Subscript out of range” error
that could be received during zeroing of analog
channels in OrionNet.
- Eliminated issue of “Devmode
= Null” error when the user right-clicked the
strip chart to print.
8.0.14
- Added ability to import
EMU files that contain renamed channels.
- Updated “About Orion” to
display installed version instead of executable version.
- Eliminated the need for
a special authorization key in order to utilize Data
Simulator.
- Added ability to start
the Fatigue Monitor from outside “Quickstart”.
8.0.13
- For
Orion IV Users Only - eliminated
runtime error 6 (Not a Number) during Orion IV
data acquisition.
8.0.12
- Eliminated the Playback
error “Invalid use of Null” that would
occur if no channels were available upon initiation
of database Playback.
- Added ability to use Configuration
utility for computers without a COM port present.
- For
Orion IV Users Only - Corrected
Microsoft incompatibility issue that resulted in
a “Automation Error” when using Ultimate
I/O.
- Corrected an issue in
Log Tool/Report Designer that caused blank pages to
be printed if the print icon was used to print during
real-time data acquisition.
8.0.10
- Updated “uninstall” functionality
to prevent accidental removal of data files.
- Corrected an issue such
that Fatigue Monitor and Limits Monitor will launch
correctly.
- Critical Update if Using
Metric Units: Corrected an issue where Limits Monitor
would be scaled incorrectly if metric units were used.
- Orion version 8 user's
guide added to the help menu.
8.0.08
- Corrected an issue that
caused Orion to be unstable when resuming real-time
acquisition if comments were contained at some location
other than in the right-hand column.
- Corrected the calibration
wizard so it can be used for Depth/Speed channel calibration.
8.0.06
- Allow users
to set minimum scale value to zero in strip chart view.
- Eliminated the “Error
9” message when applying a filter to the data.
- Corrected a file menu
option such that Orion can be restarted from this location.
8.0.07
- Corrected
issue of strip charts adding 1 unit of measure to value
displayed on graph.
- Corrected an issue that caused Orion to be unstable
if the configuration contained an invalid channel type.
Go